Filter the list by product size.
Operating Pressure |
Flow Rate |
Product Code |
Price |
Stock |
3D |
Add to Cart |
6.3 Mpa
|
25 ml / s.
|
SSY6 |
|
|
|
|
Testing of System with Manual Pressure Test Pump:
Complete the mounting of Tie Bar (handle) with screw and screwdriver involved in product that you purchased.
Fill Test Hose (2) with water (air inside the hose should be discharged). Close Valve (1) on the tie bar (handle), connect testing hose to the mould (ensure that system is closed completely).
Fill the tank with water and run pump by pushing keep Valve (1) open, continue to pumping.
When Manometer (3) pressures is reached to desired level, close the Valve (1).
If the pressure does not fall, the result is positive.
If the pressures fall, there is a leak.